How accurate is an EDF individual appliance monitor?

To try to get a feel for how accurate the EDF transmitter plug is, I simultaneously recorded our washing machine using a WattsUp meter, an EDF transmitter plug and an EDF whole-house transmitter. The WattsUp samples once a second, the EDF devices sample about once every 6 seconds. (data was collected from the EDF devices using my Nanode code and my logging script). Here are the results (click on the image for a larger version):

Watts Up versus EDF IAM versus whole house

And here's the same data but this time the EDF IAM and WattsUp are laid on top of each other. I'm happy that the EDF device is of comparable accuracy to the WattsUp, at least in this experiment:

Watts Up versus EDF IAM

One thing I need to investigate a little more is that occasionally the EDF IAM appears to give a reading which is above the theoretical max wattage an appliance can draw (13 amps x 230 volts = 2990 watts). This doesn't appear to be an RF corruption issue (because the checksum is OK). I guess it's possible that our washing machine does sometimes draw too much (but for a short enough time to mean the fuse doesn't blow). I was hoping to capture an "overload" event in the data capture I did for the graphs above but unfortunately it didn't occur. If I get time I might try recording more WattsUp signals from our washing machine.

I've just ordered another 10 EDF IAMs. When these arrive (in about 10 days) I will have a total of 14 EDF IAMs. I'll run these for a week or so. If these check out OK then I'll probably order another 15 to get to a total of 30 to monitor every appliance in my home.

Comments

I wonder if this might be related to the motor - there can be some fairly large currents involved when starting it up.

Absolutely true. The thing that makes me a little worried that the IAM is spitting out the wrong answer is that, so far, I haven't seen these "overload" spikes in the whole-house measurements (in fact I have some graphs which suggest the washing machine is drawing more on its own than the entire house all together: clearly not possible!). (I've been measuring my whole-house power using a CT clamp as well as measuring individual appliances using EDF IAMs). Of course, it's likely that these spikes last less than a second, so it's entirely possible that, by chance, the IAM catches a spike but the whole-house sensor misses it. I plan to soon install a "professional" whole-house meter which should sample once per second.

I have to say, given CurrentCost's past track record, I suspect the IAM rather than the washing machine. I don't know how these various systems go about providing their averaged reading - an instantaneous peak from a motor spinning up from stationary would be large, but that event is going to be in the order of fractions of a second.